EPDM H2 60P datasheet

Hundreds of cells, one gasket, and nothing that leaches into the membrane. Design targets, release limits and the qualification plan. Download the PDF, or check the grade against your own requirements.

EPDM H2 60P grade card: EPDM-H2-60P-01, design range −40 to 120 °C.
Pascalor
Technical data sheet
Engineered for extremes

EPDM H2 60P

EPDM-H2-60P-01

Read the code: EPDM, H2 duty (hydrogen service), 60 Shore A, P for peroxide cure, recipe 01.

Development grade. The values below are design targets, not measured results. Each target becomes a typical value, with the number of lots and the test report behind it, as testing is completed.

A 60 Shore A peroxide-cured EPDM for PEM fuel cell stack gaskets and balance-of-plant seals: low compression set at 90 to 120 °C for a low closing force over a long life, resistance to humidified hydrogen and air, acidic product water and glycol coolant, low ionic extractables, flexibility for cold starts to −40 °C, and no fluorine.

Polymer class
EPDM
Duty
H2: hydrogen service
Hardness
60 Shore A
Temperature range
-40 to 120 °C
Lead time
Trial quantities on request
Minimum order
25 kg
Issued
2026-10-28
Revision
A
Packing
Per order

Design targets and release limits

PropertyTargetLimitsUnitMethod
Hardness6055 to 65Shore AASTM D2240 / ISO 48-4, 1 s
Tensile strength10min 8MPaASTM D412 die C / ISO 37 type 2
Elongation at break350min 250%ASTM D412 die C / ISO 37 type 2
Compression set, 22 h at 120 °C12max 20%ASTM D395 method B, button
Compression set, 1,000 h at 90 °C20max 30%ISO 815-1
TR10-50max -45°CASTM D1329 / ISO 2921
Dilute sulfuric acid at pH 3, 1,000 h at 90 °C, hardness change-2-5 to 5pointsASTM D471 / ISO 1817
Ethylene glycol and water (50/50), 1,000 h at 90 °C, volume change+2max 6%ASTM D471 / ISO 1817
Ionic extractables, 168 h at 90 °C in deionised waterTo reportAgreed with the stack makerIon chromatography of the soak water

Qualification plan

The grade code says what this compound is designed for. This table says what it has passed: a duty is claimed only once its report is on file.

TestStandard or methodConditionsStatus
Acid ageingIn-house method, published with resultsDilute H2SO4 at pH 3, 90 °C, 1,000 h, with compression set and stress relaxationPlanned
Coolant ageingASTM D471 / ISO 181750/50 ethylene glycol and water at 90 °C, 1,000 hPlanned
ExtractablesIon chromatography and conductivity of the soak water168 h at 90 °C in deionised waterPlanned
Compression stress relaxationISO 3384At 90 °C and 120 °C, 1,000 hPlanned
Stack qualificationIEC 62282 series, with a stack makerOn the customer's bipolar platesPlanned

Design targets are the values the compound is designed to reach. They are not measured results and they are not a warranty. Release limits apply to lots once the recipe is approved. The grade code says what the compound is designed for; the qualification plan says what it has passed. Confirm suitability in your own application and fluids.

Every lot is supplied with a certificate of analysis. Enter the lot ID under Track on the website to see the lot record. Pascalor is an independent brand and is not affiliated with any polymer manufacturer named elsewhere on this site.

Registered entity name to be added | quotes@pascalor.com