EPDM H2 75P datasheet

Hot potash or pure water and oxygen: one EPDM for the electrolyser stack. Design targets, release limits and the qualification plan. Download the PDF, or check the grade against your own requirements.

EPDM H2 75P grade card: EPDM-H2-75P-01, design range −40 to 120 °C.
Pascalor
Technical data sheet
Engineered for extremes

EPDM H2 75P

EPDM-H2-75P-01

Read the code: EPDM, H2 duty (hydrogen service), 75 Shore A, P for peroxide cure, recipe 01.

Development grade. The values below are design targets, not measured results. Each target becomes a typical value, with the number of lots and the test report behind it, as testing is completed.

A 75 Shore A peroxide-cured EPDM for electrolyser stacks and their balance of plant: resistance to 25 to 30 % potassium hydroxide at 85 °C in alkaline stacks, to deionised water and oxygen in PEM stacks, low extractables to protect membranes and catalysts, and no fluorine in the formulation.

Polymer class
EPDM
Duty
H2: hydrogen service
Hardness
75 Shore A
Temperature range
-40 to 120 °C
Lead time
Trial quantities on request
Minimum order
25 kg
Issued
2026-10-28
Revision
A
Packing
Per order

Design targets and release limits

PropertyTargetLimitsUnitMethod
Hardness7570 to 80Shore AASTM D2240 / ISO 48-4, 1 s
Specific gravity1.12±0.02 of approved valueASTM D297 / ISO 2781
Tensile strength14min 11MPaASTM D412 die C / ISO 37 type 2
Elongation at break300min 200%ASTM D412 die C / ISO 37 type 2
Compression set, 22 h at 150 °C12max 20%ASTM D395 method B, button
TR10-45max -40°CASTM D1329 / ISO 2921
30 % KOH, 1,000 h at 85 °C, volume change+3max 8%ASTM D471 / ISO 1817
30 % KOH, 1,000 h at 85 °C, hardness change-3-8 to 5pointsASTM D471 / ISO 1817
Deionised water, 1,000 h at 90 °C, volume change+3max 8%ASTM D471 / ISO 1817
Ionic extractables, 168 h at 90 °C in deionised waterTo reportAgreed with the stack makerConductivity and ion chromatography of the soak water

Qualification plan

The grade code says what this compound is designed for. This table says what it has passed: a duty is claimed only once its report is on file.

TestStandard or methodConditionsStatus
Electrolyte ageingIn-house method, published with results25 to 30 % KOH at 85 °C for 1,000 h and 3,000 h, free and compressed: volume, hardness, tensile and compression setPlanned
Water and oxygen ageingIn-house method, published with resultsDeionised water and oxygen-saturated water at 80 to 90 °C for 1,000 hPlanned
ExtractablesConductivity and ion chromatography of the soak waterIons and organics released in 168 h at 90 °CPlanned
Hydrogen permeabilityISO 2782-1Hydrogen at 23 °C and 80 °CPlanned
Stack qualificationISO 22734 system requirements, with an electrolyser makerOn the customer's stack designPlanned

Design targets are the values the compound is designed to reach. They are not measured results and they are not a warranty. Release limits apply to lots once the recipe is approved. The grade code says what the compound is designed for; the qualification plan says what it has passed. Confirm suitability in your own application and fluids.

Every lot is supplied with a certificate of analysis. Enter the lot ID under Track on the website to see the lot record. Pascalor is an independent brand and is not affiliated with any polymer manufacturer named elsewhere on this site.

Registered entity name to be added | quotes@pascalor.com