EPDM Steam 75P grade card: EPDM-STM75P-01, design range −45 to 160 °C.
Pascalor
Technical data sheet
Engineered for extremes

EPDM Steam 75P

EPDM-STM75P-01

Read the code: EPDM, STM duty (steam and hot water), 75 Shore A, P for peroxide cure, recipe 01.

Development grade. The values below are design targets, not measured results. Each target becomes a typical value, with the number of lots and the test report behind it, as testing is completed.

A 75 Shore A peroxide-cured EPDM for steam, hot water, condensate and cooling water in thermal power plants: boiler feed and condensate pumps, valves, heat exchanger gaskets and expansion joints. Not for mineral oils.

Polymer class
EPDM
Duty
STM: steam and hot water
Hardness
75 Shore A
Temperature range
-45 to 160 °C
Lead time
Trial quantities on request
Minimum order
25 kg
Issued
2026-10-28
Revision
A
Packing
Per order

Design targets and release limits

PropertyTargetLimitsUnitMethod
Hardness7570 to 80Shore AASTM D2240 / ISO 48-4, 1 s
Specific gravity1.12±0.02 of approved valueASTM D297 / ISO 2781
Tensile strength14min 11MPaASTM D412 die C / ISO 37 type 2
Elongation at break250min 180%ASTM D412 die C / ISO 37 type 2
Compression set, 22 h at 150 °C12max 20%ASTM D395 method B, button
TR10-45max -40°CASTM D1329 / ISO 2921
Saturated steam, 168 h at 180 °C, hardness change-2-5 to 5pointsIn-house autoclave method
Saturated steam, 168 h at 180 °C, volume change+3max 8%In-house autoclave method
Hot water, 1,000 h at 150 °CTo be measuredReported, no limit yetLong-term ageing (planned)
Mineral oil (IRM 903)Not suitable—EPDM swells in mineral oils

Qualification plan

The grade code says what this compound is designed for. This table says what it has passed: a duty is claimed only once its report is on file.

TestStandard or methodConditionsStatus
Steam ageingIn-house autoclave method, published with results168 h and 500 h at 160 °C and 180 °CPlanned
Hot water ageingLong-term immersion1,000 h at 150 °CPlanned
Pump OEM approvalCustomer qualificationOn boiler feed and condensate pump sealsPlanned

Design targets are the values the compound is designed to reach. They are not measured results and they are not a warranty. Release limits apply to lots once the recipe is approved. The grade code says what the compound is designed for; the qualification plan says what it has passed. Confirm suitability in your own application and fluids.