EPDM Swell 70S datasheet

An element that grows into the hole. Design targets, release limits and the qualification plan. Download the PDF, or check the grade against your own requirements.

EPDM Swell 70S grade card: EPDM-SWELL70S-01, design range −40 to 150 °C.
Pascalor
Technical data sheet
Engineered for extremes

EPDM Swell 70S

EPDM-SWELL70S-01

Read the code: EPDM, SWELL duty (swellable elements), 70 Shore A, S for sulfur cure, recipe 01.

Development grade. The values below are design targets, not measured results. Each target becomes a typical value, with the number of lots and the test report behind it, as testing is completed.

A 70 Shore A EPDM that swells in hydrocarbons for swellable packers: it seals irregular open holes and annuli by absorbing oil, without mechanical setting.

Polymer class
EPDM
Duty
SWELL: swellable elements
Hardness
70 Shore A
Temperature range
-40 to 150 °C
Lead time
Trial quantities on request
Minimum order
25 kg
Issued
2026-10-28
Revision
A
Packing
Per order

Design targets and release limits

PropertyTargetLimitsUnitMethod
Hardness7065 to 75Shore AASTM D2240 / ISO 48-4, 1 s
Tensile strength12min 10MPaASTM D412 die C / ISO 37 type 2
Elongation at break450min 350%ASTM D412 die C / ISO 37 type 2
IRM 903, 168 h at 90 °C, volume swell+150min 120%ASTM D471 / ISO 1817
Swell rate curveTo be measuredReported, no limit yetIn customer fluid at temperature
Pressure held by swollen elementTo be measuredReported, no limit yetMPaIn-house test fixture

Qualification plan

The grade code says what this compound is designed for. This table says what it has passed: a duty is claimed only once its report is on file.

TestStandard or methodConditionsStatus
Swell rateIn-house method, published with resultsIn customer crude or kerosene at well temperaturePlanned
Pressure holdingIn-house fixtureAfter swellingPlanned

Design targets are the values the compound is designed to reach. They are not measured results and they are not a warranty. Release limits apply to lots once the recipe is approved. The grade code says what the compound is designed for; the qualification plan says what it has passed. Confirm suitability in your own application and fluids.

Every lot is supplied with a certificate of analysis. Enter the lot ID under Track on the website to see the lot record. Pascalor is an independent brand and is not affiliated with any polymer manufacturer named elsewhere on this site.

Registered entity name to be added | quotes@pascalor.com