Engineered for extremes
FKM Chemical 90P
Read the code: FKM, CHEM duty (chemical resistance), 90 Shore A, P for peroxide cure, recipe 01.
Development grade. The values below are design targets, not measured results. Each target becomes a typical value, with the number of lots and the test report behind it, as testing is completed.
A 90 Shore A base-resistant FKM for amines, high-pH completion fluids, steam and sour gas to 210 °C, with better low-temperature flexibility and compression set than FEPM.
- Polymer class
- FKM
- Duty
- CHEM: chemical resistance
- Pole mark
- HPHT
- Hardness
- 90 Shore A
- Temperature range
- -10 to 210 °C
- Lead time
- Trial quantities on request
- Minimum order
- 25 kg
- Issued
- 2026-10-28
- Revision
- A
- Packing
- Per order
Design targets and release limits
| Property | Target | Limits | Unit | Method |
|---|---|---|---|---|
| Hardness | 90 | 85 to 95 | Shore A | ASTM D2240 / ISO 48-4, 1 s |
| Specific gravity | 1.8 | ±0.02 of approved value | ASTM D297 / ISO 2781 | |
| Tensile strength | 14 | min 11 | MPa | ASTM D412 die C / ISO 37 type 2 |
| Elongation at break | 120 | min 90 | % | ASTM D412 die C / ISO 37 type 2 |
| Compression set, 70 h at 200 °C | 25 | max 35 | % | ASTM D395 method B, button |
| TR10 | -8 | max -5 | °C | ASTM D1329 / ISO 2921 |
| 5 % amine in water, 168 h at 150 °C, volume change | +4 | max 10 | % | ASTM D471 / ISO 1817 |
| 5 % amine in water, 168 h at 150 °C, tensile change | -20 | max -35 | % | ASTM D471 / ISO 1817 |
| Saturated steam, 168 h at 200 °C, volume change | +3 | max 8 | % | In-house autoclave method |
| IRM 903, 168 h at 150 °C, volume change | +4 | max 10 | % | ASTM D471 / ISO 1817 |
Qualification plan
The grade code says what this compound is designed for. This table says what it has passed: a duty is claimed only once its report is on file.
| Test | Standard or method | Conditions | Status |
|---|---|---|---|
| Amine and steam ageing | In-house method, published with results | Amine inhibitor and saturated steam at rated temperature | Planned |
| Sour ageing and life prediction | ISO 23936-2 Annex A / NORSOK M-710 | Sour multiphase fluid (hydrocarbon liquid, water, gas with H2S) at three temperatures; Arrhenius extrapolation to service temperature | Planned |
| Rapid gas decompression | ISO 23936-2 Annex B / NORSOK M-710 | 90/10 CH4/CO2, 15 MPa, 100 °C, 8 cycles, about 2 MPa/min decompression; 5.33 mm and 6.99 mm sections; target rating 0000 to 1111 (0 to 3 passes) | Planned |
| Elastomer immersion | API 6A Annex F, material class FF/HH | 10 % H2S / 80 % CO2 / 10 % CH4 gas phase, at least 6.9 MPa, at least 160 h at 177 °C; NORSOK-style acceptance limits | Planned |
Design targets are the values the compound is designed to reach. They are not measured results and they are not a warranty. Release limits apply to lots once the recipe is approved. The grade code says what the compound is designed for; the qualification plan says what it has passed. Confirm suitability in your own application and fluids.