FKM CO2 90P datasheet

For CO2 that is dense, cold on release and full of methanol. Design targets, release limits and the qualification plan. Download the PDF, or check the grade against your own requirements.

FKM CO2 90P grade card: FKM-CO2-90P-01, design range −40 to 200 °C.
Pascalor
Technical data sheet
Engineered for extremes

FKM CO2 90P

FKM-CO2-90P-01

Read the code: FKM, CO2 duty (carbon dioxide service), 90 Shore A, P for peroxide cure, recipe 01.

Development grade. The values below are design targets, not measured results. Each target becomes a typical value, with the number of lots and the test report behind it, as testing is completed.

A 90 Shore A FKM for carbon capture and storage, CO2 injection and methanol-dosed gas systems: designed for decompression in 100 % CO2, methanol resistance and low-temperature sealing to −40 °C.

Polymer class
FKM
Duty
CO2: carbon dioxide service
Pole mark
HPHT and HPLT
Hardness
90 Shore A
Temperature range
-40 to 200 °C
Lead time
Trial quantities on request
Minimum order
25 kg
Issued
2026-10-28
Revision
A
Packing
Per order

Design targets and release limits

PropertyTargetLimitsUnitMethod
Hardness9085 to 95Shore AASTM D2240 / ISO 48-4, 1 s
Specific gravity1.87±0.02 of approved valueASTM D297 / ISO 2781
Tensile strength14min 11MPaASTM D412 die C / ISO 37 type 2
Elongation at break130min 100%ASTM D412 die C / ISO 37 type 2
Compression set, 22 h at 200 °C20max 30%ASTM D395 method B, button
TR10-28max -26°CASTM D1329 / ISO 2921
Low-temperature sealing (product test)-40no leak at −40°CProduct-configured O-ring test at pressure
Methanol, 168 h at 40 °C, volume change+8max 15%ASTM D471 / ISO 1817

Qualification plan

The grade code says what this compound is designed for. This table says what it has passed: a duty is claimed only once its report is on file.

TestStandard or methodConditionsStatus
Rapid gas decompression in CO2ISO 23936-2 Annex B adapted to 100 % CO215 MPa, 50 to 100 (to be confirmed) °C, 8 cycles, 5.33 mm and 6.99 mm sectionsPlanned
CO2 decompressionNACE TM0297Per standardPlanned
Methanol immersionASTM D471With dry-out and re-testPlanned
Low-temperature sealingProduct-configured O-ring test (method published with the report)Sealing at −40 °C at rated pressure; leak onset temperature reported with TR10 of the same lotPlanned

Design targets are the values the compound is designed to reach. They are not measured results and they are not a warranty. Release limits apply to lots once the recipe is approved. The grade code says what the compound is designed for; the qualification plan says what it has passed. Confirm suitability in your own application and fluids.

Every lot is supplied with a certificate of analysis. Enter the lot ID under Track on the website to see the lot record. Pascalor is an independent brand and is not affiliated with any polymer manufacturer named elsewhere on this site.

Registered entity name to be added | quotes@pascalor.com