HNBR H2 80P datasheet

700 bar and −40 °C: the hydrogen dispenser's day. Design targets, release limits and the qualification plan. Download the PDF, or check the grade against your own requirements.

HNBR H2 80P grade card: HNBR-H2-80P-01, design range −40 to 150 °C.
Pascalor
Technical data sheet
Engineered for extremes

HNBR H2 80P

HNBR-H2-80P-01

Read the code: HNBR, H2 duty (hydrogen service), 80 Shore A, P for peroxide cure, recipe 01.

Development grade. The values below are design targets, not measured results. Each target becomes a typical value, with the number of lots and the test report behind it, as testing is completed.

An 80 Shore A low-temperature HNBR for hydrogen service: decompression in 100 % hydrogen, sealing at −40 °C as fuelling protocols require, and permeation data stated.

Polymer class
HNBR
Duty
H2: hydrogen service
Pole mark
HPLT
Hardness
80 Shore A
Temperature range
-40 to 150 °C
Lead time
Trial quantities on request
Minimum order
25 kg
Issued
2026-10-28
Revision
A
Packing
Per order

Design targets and release limits

PropertyTargetLimitsUnitMethod
Hardness8075 to 85Shore AASTM D2240 / ISO 48-4, 1 s
Tensile strength20min 16MPaASTM D412 die C / ISO 37 type 2
Elongation at break220min 150%ASTM D412 die C / ISO 37 type 2
Compression set, 22 h at 150 °C20max 28%ASTM D395 method B, button
TR10-32max -30°CASTM D1329 / ISO 2921
Low-temperature sealing (product test)-40no leak at −40°CProduct-configured O-ring test at pressure
Hydrogen permeabilityTo be measuredReported, no limit yetISO 2782-1

Qualification plan

The grade code says what this compound is designed for. This table says what it has passed: a duty is claimed only once its report is on file.

TestStandard or methodConditionsStatus
Station O-ring requirementsISO 19880-7:2025, with a dispenser or valve makerUp to 70 MPa nominal working pressure, −40 °C to +65 °C, on the customer housingPlanned
Rapid decompression in hydrogenISO 23936-2 Annex B adapted to 100 % H2100 % H2 at up to 87.5 MPa, 65 °C, 8 cycles, 5.33 mm sectionPlanned
Low-temperature sealingProduct-configured O-ring test (method published with the report)Sealing at −40 °C at rated pressure; leak onset temperature reported with TR10 of the same lotPlanned
PermeabilityISO 2782-1Hydrogen at 23 °C and 65 °CPlanned
Low-temperature cyclingWith gas pre-cooled as in SAE J2601, with a dispenser makerPressure cycles at −40 °C (number agreed with the maker)Planned

Design targets are the values the compound is designed to reach. They are not measured results and they are not a warranty. Release limits apply to lots once the recipe is approved. The grade code says what the compound is designed for; the qualification plan says what it has passed. Confirm suitability in your own application and fluids.

Every lot is supplied with a certificate of analysis. Enter the lot ID under Track on the website to see the lot record. Pascalor is an independent brand and is not affiliated with any polymer manufacturer named elsewhere on this site.