HNBR Transformer 70P datasheet

A gasket that respects the insulating oil. Design targets, release limits and the qualification plan. Download the PDF, or check the grade against your own requirements.

HNBR Transformer 70P grade card: HNBR-TRF70P-01, design range −40 to 130 °C.
Pascalor
Technical data sheet
Engineered for extremes

HNBR Transformer 70P

HNBR-TRF70P-01

Read the code: HNBR, TRF duty (transformers and electrical equipment), 70 Shore A, P for peroxide cure, recipe 01.

Development grade. The values below are design targets, not measured results. Each target becomes a typical value, with the number of lots and the test report behind it, as testing is completed.

A 70 Shore A HNBR for transformer, switchgear and electrical equipment gaskets in mineral oil and in natural and synthetic esters: low compression set at temperature, low-temperature flexibility and a fluorine-free formulation.

Polymer class
HNBR
Duty
TRF: transformers and electrical equipment
Hardness
70 Shore A
Temperature range
-40 to 130 °C
Lead time
Trial quantities on request
Minimum order
25 kg
Issued
2026-10-28
Revision
A
Packing
Per order

Design targets and release limits

PropertyTargetLimitsUnitMethod
Hardness7065 to 75Shore AASTM D2240 / ISO 48-4, 1 s
Tensile strength20min 16MPaASTM D412 die C / ISO 37 type 2
Elongation at break350min 250%ASTM D412 die C / ISO 37 type 2
Compression set, 70 h at 125 °C18max 25%ASTM D395 method B, button
TR10-35max -30°CASTM D1329 / ISO 2921
Mineral insulating oil (IEC 60296), 168 h at 125 °C, volume change+5max 10%ASTM D471 / ISO 1817
Natural ester (IEC 62770), 168 h at 125 °C, volume change+8max 15%ASTM D471 / ISO 1817
Compatibility with insulating oilPasspassASTM D3455

Qualification plan

The grade code says what this compound is designed for. This table says what it has passed: a duty is claimed only once its report is on file.

TestStandard or methodConditionsStatus
Material compatibility with insulating oilASTM D3455Mineral oil, natural and synthetic esterPlanned
Fluid immersionASTM D471Mineral oil, natural ester, synthetic ester at 125 °CPlanned
Transformer OEM approvalCustomer qualificationPer OEMPlanned

Design targets are the values the compound is designed to reach. They are not measured results and they are not a warranty. Release limits apply to lots once the recipe is approved. The grade code says what the compound is designed for; the qualification plan says what it has passed. Confirm suitability in your own application and fluids.

Every lot is supplied with a certificate of analysis. Enter the lot ID under Track on the website to see the lot record. Pascalor is an independent brand and is not affiliated with any polymer manufacturer named elsewhere on this site.

Registered entity name to be added | quotes@pascalor.com