NBR General 70S grade card: NBR-GEN70S-01, design range −30 to 110 °C.
Pascalor
Technical data sheet
Engineered for extremes

NBR General 70S

NBR-GEN70S-01

Read the code: NBR, GEN duty (general reference grade), 70 Shore A, S for sulfur cure, recipe 01.

Development grade. The values below are design targets, not measured results. Each target becomes a typical value, with the number of lots and the test report behind it, as testing is completed.

A 70 Shore A sulfur-cured NBR for general O-rings and seals in mineral oils, greases, water and glycols to about 110 °C: the grade most seal lines run every day, supplied with the same lot data as the premium range.

Polymer class
NBR
Duty
GEN: general reference grade
Hardness
70 Shore A
Temperature range
-30 to 110 °C
Lead time
Trial quantities on request
Minimum order
25 kg
Issued
2026-10-28
Revision
A
Packing
Per order

Design targets and release limits

PropertyTargetLimitsUnitMethod
Hardness7065 to 75Shore AASTM D2240 / ISO 48-4, 1 s
Specific gravity1.25±0.02 of approved valueASTM D297 / ISO 2781
Tensile strength15min 12MPaASTM D412 die C / ISO 37 type 2
Elongation at break380min 300%ASTM D412 die C / ISO 37 type 2
Compression set, 22 h at 100 °C12max 20%ASTM D395 method B, button
TR10-25max -22°CASTM D1329 / ISO 2921
IRM 903, 70 h at 100 °C, volume change+10max 15%ASTM D471 / ISO 1817
Heat ageing 70 h at 100 °C, hardness change+50 to 8pointsASTM D573 / ISO 188

Qualification plan

The grade code says what this compound is designed for. This table says what it has passed: a duty is claimed only once its report is on file.

TestStandard or methodConditionsStatus
Specification call-outASTM D2000 line call-outTo be issued with the first production dataPlanned
Customer approvalsSeal maker qualificationPer customerPlanned

Design targets are the values the compound is designed to reach. They are not measured results and they are not a warranty. Release limits apply to lots once the recipe is approved. The grade code says what the compound is designed for; the qualification plan says what it has passed. Confirm suitability in your own application and fluids.

Every lot is supplied with a certificate of analysis. Enter the lot ID under Track on the website to see the lot record. Pascalor is an independent brand and is not affiliated with any polymer manufacturer named elsewhere on this site.