NBR General 90S datasheet

Hard nitrile for oilfield pressure. Design targets, release limits and the qualification plan. Download the PDF, or check the grade against your own requirements.

NBR General 90S grade card: NBR-GEN90S-01, design range −25 to 121 °C.
Pascalor
Technical data sheet
Engineered for extremes

NBR General 90S

NBR-GEN90S-01

Read the code: NBR, GEN duty (general reference grade), 90 Shore A, S for sulfur cure, recipe 01.

Development grade. The values below are design targets, not measured results. Each target becomes a typical value, with the number of lots and the test report behind it, as testing is completed.

A 90 Shore A sulfur-cured NBR for oilfield and hydraulic seals where pressure and extrusion matter more than temperature, targeted at API 6A temperature class U (to 121 °C) after immersion testing.

Polymer class
NBR
Duty
GEN: general reference grade
Hardness
90 Shore A
Temperature range
-25 to 121 °C
Lead time
Trial quantities on request
Minimum order
25 kg
Issued
2026-10-28
Revision
A
Packing
Per order

Design targets and release limits

PropertyTargetLimitsUnitMethod
Hardness9085 to 95Shore AASTM D2240 / ISO 48-4, 1 s
Specific gravity1.28±0.02 of approved valueASTM D297 / ISO 2781
Tensile strength16min 13MPaASTM D412 die C / ISO 37 type 2
Elongation at break150min 110%ASTM D412 die C / ISO 37 type 2
Modulus at 100 %108 to 13MPaASTM D412 die C / ISO 37 type 2
Compression set, 22 h at 100 °C15max 25%ASTM D395 method B, button
TR10-20max -18°CASTM D1329 / ISO 2921
IRM 903, 70 h at 100 °C, volume change+5max 10%ASTM D471 / ISO 1817

Qualification plan

The grade code says what this compound is designed for. This table says what it has passed: a duty is claimed only once its report is on file.

TestStandard or methodConditionsStatus
Elastomer immersionAPI 6A Annex F, sweet material classes (AA to CC)At least 160 h at 121 °C (temperature class U)Planned
Rapid gas decompression (optional)ISO 23936-2 Annex BAs for the RGD gradesPlanned
Specification call-outASTM D2000 line call-outTo be issuedPlanned

Design targets are the values the compound is designed to reach. They are not measured results and they are not a warranty. Release limits apply to lots once the recipe is approved. The grade code says what the compound is designed for; the qualification plan says what it has passed. Confirm suitability in your own application and fluids.

Every lot is supplied with a certificate of analysis. Enter the lot ID under Track on the website to see the lot record. Pascalor is an independent brand and is not affiliated with any polymer manufacturer named elsewhere on this site.