NBR H2 70P datasheet

For the gas grid as the hydrogen share goes up. Design targets, release limits and the qualification plan. Download the PDF, or check the grade against your own requirements.

NBR H2 70P grade card: NBR-H2-70P-01, design range −30 to 100 °C.
Pascalor
Technical data sheet
Engineered for extremes

NBR H2 70P

NBR-H2-70P-01

Read the code: NBR, H2 duty (hydrogen service), 70 Shore A, P for peroxide cure, recipe 01.

Development grade. The values below are design targets, not measured results. Each target becomes a typical value, with the number of lots and the test report behind it, as testing is completed.

A 70 Shore A peroxide-cured NBR for seals and diaphragms in gas distribution and gas appliances carrying natural gas blended with hydrogen, up to 100 % hydrogen: low hydrogen permeation for a nitrile and low compression set, with DVGW ZP 5101 and EN 549 testing planned.

Polymer class
NBR
Duty
H2: hydrogen service
Hardness
70 Shore A
Temperature range
-30 to 100 °C
Lead time
Trial quantities on request
Minimum order
25 kg
Issued
2026-10-28
Revision
A
Packing
Per order

Design targets and release limits

PropertyTargetLimitsUnitMethod
Hardness7065 to 75Shore AASTM D2240 / ISO 48-4, 1 s
Specific gravity1.24±0.02 of approved valueASTM D297 / ISO 2781
Tensile strength14min 11MPaASTM D412 die C / ISO 37 type 2
Elongation at break350min 250%ASTM D412 die C / ISO 37 type 2
Compression set, 22 h at 100 °C12max 20%ASTM D395 method B, button
Compression set, 1,000 h at 70 °C20max 30%ISO 815-1
TR10-28max -25°CASTM D1329 / ISO 2921
IRM 903, 70 h at 100 °C, volume change+5max 10%ASTM D471 / ISO 1817
Hydrogen permeability, 23 °CTo reportReported, no limit yetISO 15105-1 / ISO 2782-1

Qualification plan

The grade code says what this compound is designed for. This table says what it has passed: a duty is claimed only once its report is on file.

TestStandard or methodConditionsStatus
Hydrogen compatibility and permeationDVGW ZP 5101 (to 100 vol.% H2)Certification testing at an approved laboratoryPlanned
Gas appliance seal materialsEN 549Class and temperature range agreed with the appliance or regulator makerPlanned
Hydrogen permeabilityISO 15105-1 / ISO 2782-1Hydrogen at 23 °CPlanned
Long-term compression setISO 815-11,000 h at 70 °CPlanned
Rapid gas decompression (optional module)DVGW ZP 5101 RGD extension (December 2025)Where the network sees fast pressure changesPlanned

Design targets are the values the compound is designed to reach. They are not measured results and they are not a warranty. Release limits apply to lots once the recipe is approved. The grade code says what the compound is designed for; the qualification plan says what it has passed. Confirm suitability in your own application and fluids.

Every lot is supplied with a certificate of analysis. Enter the lot ID under Track on the website to see the lot record. Pascalor is an independent brand and is not affiliated with any polymer manufacturer named elsewhere on this site.