NBR Swell 60S datasheet

For zones where the water arrives first. Design targets, release limits and the qualification plan. Download the PDF, or check the grade against your own requirements.

NBR Swell 60S grade card: NBR-SWELL60S-01, design range −20 to 120 °C.
Pascalor
Technical data sheet
Engineered for extremes

NBR Swell 60S

NBR-SWELL60S-01

Read the code: NBR, SWELL duty (swellable elements), 60 Shore A, S for sulfur cure, recipe 01.

Development grade. The values below are design targets, not measured results. Each target becomes a typical value, with the number of lots and the test report behind it, as testing is completed.

A 60 Shore A nitrile compound containing a superabsorbent polymer, for water-swell packers and seals in water-producing zones up to about 120 °C. Swelling is fastest in fresh water and slows as salinity rises.

Polymer class
NBR + SAP
Duty
SWELL: swellable elements
Hardness
60 Shore A
Temperature range
-20 to 120 °C
Lead time
Trial quantities on request
Minimum order
25 kg
Issued
2026-10-28
Revision
A
Packing
Per order

Design targets and release limits

PropertyTargetLimitsUnitMethod
Hardness6055 to 65Shore AASTM D2240 / ISO 48-4, 1 s
Tensile strength8min 6MPaASTM D412 die C / ISO 37 type 2
Elongation at break400min 300%ASTM D412 die C / ISO 37 type 2
Volume swell, deionised water, 7 days at 90 °C+200min 150%ASTM D471 / ISO 1817
Volume swell, 3 % NaCl, 7 days at 90 °C+120min 80%ASTM D471 / ISO 1817
Maximum service temperature120max 120°CDesign limit

Qualification plan

The grade code says what this compound is designed for. This table says what it has passed: a duty is claimed only once its report is on file.

TestStandard or methodConditionsStatus
Swell rate in brinesIn-house method, published with resultsCustomer brine at well temperaturePlanned
Pressure holdingIn-house fixtureAfter swellingPlanned

Design targets are the values the compound is designed to reach. They are not measured results and they are not a warranty. Release limits apply to lots once the recipe is approved. The grade code says what the compound is designed for; the qualification plan says what it has passed. Confirm suitability in your own application and fluids.

Every lot is supplied with a certificate of analysis. Enter the lot ID under Track on the website to see the lot record. Pascalor is an independent brand and is not affiliated with any polymer manufacturer named elsewhere on this site.

Registered entity name to be added | quotes@pascalor.com