Ionising radiation changes polymers by scission (breaking chains) and crosslinking. Which effect dominates depends on structure.
Typical tolerance (order of magnitude, dose in kGy)
| Material | Approximate tolerable dose |
|---|---|
| PTFE | Low, about 10 to 50 kGy before strength loss |
| FKM | About 100 to 500 kGy |
| Silicone | About 100 to 300 kGy, softening and hardening varies |
| EPDM (peroxide) | About 1,000 kGy or more with suitable compound |
| Nitrile | About 500 kGy |
| PEEK | About 10,000 kGy |
| Polyimide | About 10,000 kGy and above |
| Polyurethane | Moderate |
These are indicative. Compound formulation, dose rate, temperature and oxygen change results.
Nuclear power seals
- EPDM compounds are standard for reactor primary and containment seals, with strict qualification for radiation, steam and loss-of-coolant accident conditions.
- Standards include IEEE 323 and IEEE 383 (equipment qualification) and ASME Section III (nuclear components); national regulators add rules.
- Compounds are produced with controlled raw materials and full batch traceability under a nuclear quality programme such as ISO 9001 with ASME NQA-1 where required.
Sterilisation
Gamma sterilisation of medical and pharma assemblies typically uses 25 to 50 kGy. PTFE, silicone and some elastomers change under this dose; qualify the real seal after irradiation. E-beam and ethylene oxide are alternatives.
Design hints
- Choose a material with a dose margin of at least a factor of two.
- Peroxide-cured, non-sulphur, low-plasticiser compounds hold up better.
- Specify dose rate, temperature and air or inert atmosphere during test.
- Replace on a schedule.
Documentation
Nuclear and medical buyers audit suppliers. Be ready with material certificates, process control plans, and a change-notification agreement.