Looking at the failed ring is the quickest route to the cause.
| Failure | What you see | Likely cause | Fix |
|---|---|---|---|
| Compression set | Flat, permanently deformed section, no tears | Too much heat, wrong polymer, insufficient cure, overfilled groove | Better compound, lower temperature, correct groove |
| Extrusion | Ragged edge on the low-pressure side | Gap too large, pressure too high, rubber too soft | Back-up ring, harder compound, smaller gap |
| Spiral failure | Twisted spiral cuts around the ring | Rough surface, long stroke, side load, wrong groove | Quad ring, better finish, lower friction |
| Abrasion | Flat shiny worn area on the dynamic face | Rough surface, dirt, poor lubrication | Fine finish, filters, compatible lubricant |
| Thermal degradation | Cracks, hardening, surface crazing, brittleness | Temperature too high | Higher grade polymer |
| Chemical attack | Swelling, softening, shrinkage, loss of weight | Fluid not compatible | Change polymer after a compatibility test |
| Installation damage | Cuts, nicks, twisted ring | Sharp edges, tools, dirt | Chamfers, lubricant, installation tool, assembly training |
| Explosive decompression | Blisters, internal splits, pocks | Gas dissolved at pressure expands when pressure drops | Use RGD-resistant compound, harder, tougher, vented design |
| Ozone cracking | Fine surface cracks at stressed zones | Ozone on susceptible rubber | EPDM, FKM or antiozonant compound |
| Plasticiser extraction | Shrinkage, hardening in service | Fluid pulls out plasticiser | Plasticiser-free compound |
How to investigate
- Photograph the ring as received, before cleaning.
- Note where on the ring and which side of the gland the damage is.
- Measure cross-section, hardness and weight against the new part.
- Check the groove and shaft for wear, burrs and finish.
- Review fluid, temperature and pressure history, especially upsets.
- Cut a section to see internal damage.
Root cause thinking
Many rings fail from a combination: a ring with marginal compression set in a groove that was a little too deep, at a temperature 20 degrees above design. Fix the margin, not only the symptom.
Records
Keep the failed ring and the lot number. Lot traceability lets you separate a material problem from a design problem.